Sika Top Seal 107 Cementitious Waterproofing & Protective Coating 25KG Set (Part A: 20KG + Part B: 5KG)
Sika Top Seal 107 Cementitious Waterproofing & Protective Coating 25KG Set (Part A: 20KG + Part B: 5KG)
- Brand Sika
- Model: SK-TS107-25
Description
• Previously known as SikaTop® Seal-107.
• SikaTop® Seal-107 (MY) is a two part polymer modified cementitious waterproof mortar slurry comprising of a liquid polymer and a cement based mix incorporating special admixtures. It is applied to concrete and mortar to prevent water infiltration.
Characteristics / Advantages
• Pre-batched components - mixes and applies easily.
• Slurry or trowellable consistency.
• Good adhesion to sound, prepared substrates.
• Increased frost and salt resistance.
• Protects against concrete carbonation and water penetration.
• Non-toxic - suitable for contact with drinking water.
• Non-corrosive to steel and iron.
Specification
Product Information
• Composition:
- Part A: Liquid polymer and additive
- Part B: Portland cement, selected aggregate and additives
• Packaging:
- Part A: 5 kg can
- Part B: 20 kg bag
- Part A+B: 25 kg set
• Appearance / Colour:
- Part A: White liquid
- Part B: Grey powder
- Part A+B: Grey slurry
• Shelf Life: 6 months from the date of production
• Storage Conditions: Stored properly in original, unopened and undamaged sealed packaging in dry conditions. Protect from direct sunlight, rain, water and moisture.
Technical Information
• Tensile Adhesion Strength:
~0.7 N/mm² (EN 1542)
- Tested under laboratory controlled conditions. Results may vary at site conditions.
• Permeability to Water Vapour: < 5 m (EN ISO 7783-1 & 7783-2)
• Capillary Absorption: < 0.1 kg/m².h 0.5 (EN 1062-3)
• Permeability to Carbon Dioxide: > 50 m (EN 1062-6)
Application Information
• Fresh Mortar Density: 1.9–2.0 kg/l
• Consumption:
- Waterproofing bathrooms, terraces and balconies is 1.0 kg/m² per coat.
- Waterproofing coating more than 1 m waterhead is 1.5 kg/m² per coat.
- As a protective coating is 2.0 kg/m² per coat.
Notes:
- SikaTop® Seal-107 (MY) must be applied in minimum of 2 coats, including upturns up to 300 mm height.
- 3 coats may be required in areas of extremely high infiltration.
- For upturn more 300 mm height, please contact Sika's Technical Service Department.
• Pot Life: ~30 minutes (at +30 °C). Pot life will be shortened at higher temperatures.
• Waiting Time / Overcoating:
Waiting Time
- The waiting time between coats is 4–8 hours (at +30 °C).
Overcoating
- For overcoating with other cementitious materials, allow the second coat to harden for at least 3 days prior to overcoating.
- For use in water-retaining structures or for applying renders over it or for overcoating with non-cementitious materials, please contact Sika's Technical Service Department.
• Curing Treatment: Generally not required but precautions should be taken for applications done directly under sunlight and windy conditions.
Uses
SikaTop Seal-107 (MY) is used for:
• Interior and exterior waterproofing and damp-proofing of concrete, cementitious rendering, brickwork and blockwork.
• Protection of concrete structures against the effects of de-icing salts and freeze-thaw attacks.
• Exterior waterproofing of basement walls in new construction and refurbishment.
• Pore/blowhole filling.
• Rigid waterproofing of water tanks, swimming pools, etc.
• Sealing fine "hairline" cracks in concrete structures not subject to movement.
• Sealing internal basement walls against dampness.
• Levelling mortar for concrete repair works.
Areas of application
▪ Potable concrete water tanks.
▪ Basements.
▪ Terraces and balconies.
▪ Retaining walls.
▪ Fountains.
▪ RC gutters and planter boxes.
▪ Bathroom floors.
▪ Seawalls.
Application
▪ Whilst the substrate is still damp from saturation, apply the first coat.
▪ Leave to harden for approximately 4–8 hours at temperatures above 20 °C before applying the second coat.
As a slurry
▪ Apply the mixed SikaTop® Seal-107 (MY) by hand using a hard plastic bristled brush or broom.
▪ Applied in the same direction.
▪ Apply the second coat of SikaTop® Seal-107 (MY) in crosswise direction to the first application as soon as first coat has hardened.
As a mortar
▪ SikaTop® Seal-107 (MY) is applied by trowel (e.g. for a smooth surface finish), the product must be mixed with a 10 % reduction of part A.
▪ Apply the second coat of SikaTop® Seal-107 (MY) as soon as the first coat has hardened.
▪ For pore / blowhole filling, tightly trowel into the pores / blowholes of the surface.
▪ For floor applications, to avoid risk of damage to the first coat, it is recommended that the second coat be applied before 24 hours.
▪ If the second coat is applied 12 hours or later, the first coat shall be slightly prewetted, preferably by using a fine spray.
▪ After the second coat has been applied, a better finish can be achieved by rubbing down with a soft, dry sponge.
▪ For more details, please contact Sika Technical Service Department.
Important Considerations
▪ SikaTop® Seal-107 (MY) is not a decorative treatment and may display signs of “blooming” after rain or in damp weather. This does not affect the performance of the coating, in any way. Where a decorative finish is required, overpaint SikaTop® Seal-107 (MY) with any approved Sika solvent based protective and decorative coatings, e.g. Sikagard®-680 MY.
▪ Avoid application under direct sun and/or strong wind. Do not add water in any circumstances. Apply only to sound, prepared substrates - surfaces should be well dampened but free of surface water and leaks.
▪ For waterproofing or damp proofing application, always use at least 2 coats to give a total thickness of between 1.0–2.0 mm. In areas of severe water penetration, three coats might be required.
▪ Protect freshly applied material against direct sunlight, strong winds, rain and dust for at least 8 hours.
▪ SikaTop® Seal-107 (MY) does not provide a trafficable finish. Protect with screed mixed with SikaLatex® MY (Refer to SikaLatex® MY Product Data Sheet).
▪ For waterproofing / damp-proofing works, special attention is required to avoid puncturing the waterproof coating with fixings.
▪ When used in contact with potable water structures, ensure that all associated products and construction materials also comply with the local regulations for contact with potable water.